HIC-based Glyconanoparticle Characterization Service
Overview of Hydrophobic Interaction Chromatography (HIC)-based Glyconanoparticle Characterization
At CD BioGlyco, HIC-based
glyconanoparticle characterization service is part of our comprehensive GlycoNano™ Platform, designed to meet the growing needs in glycoscience research. Our
GlycoNano™ platform offers a suite of services aimed at the synthesis, analysis, and application of glyconanoparticles. One of the critical sub-services is Glyconanoparticle Characterization Service, where researchers analyze the composition, stability, and functionality of their nanoparticles. Further diving into details,
Glyconanoparticle Physicochemical Property Characterization Service provides insights into the distinct physio-chemical aspects such as size, charge, and surface properties of these particles.
Unlock Precision in Glyconanoparticle Analysis with HIC-based Characterization
HIC technology is based on the difference in hydrophobicity of the molecular surface and achieves the separation of biomacromolecules through hydrophobic interactions. For glyconanoparticles, the hydrophobic groups on their surface interact with the hydrophobic ligands on the HIC medium, so that glyconanoparticles of different hydrophobicity can be separated on the HIC column. This technology provides us with an effective means to analyze and characterize the hydrophobic properties of glyconanoparticles.
- Sample preparation: First, we pretreat the glyconanoparticle samples provided by clients, including removing impurities and adjusting concentrations to ensure the accuracy of the analysis results.
- HIC medium selection: we select suitable HIC media according to the characteristics of glyconanoparticles and client needs. These media have specific hydrophobic ligands that can effectively interact with the hydrophobic groups on the surface of glyconanoparticles.
- HIC condition optimization: In order to obtain the best separation effect, we customize the HIC conditions according to the characteristics of the sample, including selecting appropriate eluent components, ionic strength, and pH value.
- Sample loading and elution: Add the pretreated glyconanoparticle sample to the HIC column and then elute it in a high ionic strength solution environment. We achieve effective separation of glyconanoparticles with different hydrophobicity by adjusting the ionic strength of the eluent.
- Data collection and processing: During the HIC analysis process, we collect the glyconanoparticle information in the eluent in real-time, and use professional data analysis software to process and analyze the data to obtain key information such as the hydrophobicity distribution of glyconanoparticles.
We know that each client's glyconanoparticle sample is unique, so we provide customized HIC analysis services. According to the specific needs of clients and sample characteristics, we make personalized adjustments to each link of HIC analysis to ensure the accuracy and reliability of the analysis results.
Workflow
After consultation, samples are prepared and treated to optimal conditions before being subjected to HIC analysis. The samples travel through the HIC column, are separated based on hydrophobic interactions, and then analyzed. Data interpretation follows, where our scientists assess results against controls and standards, eventually concluding with a comprehensive report outlining the findings and offering recommendations for subsequent experiments or applications.
Applications of HIC-based Glyconanoparticle Characterization
- HIC technology can be used to evaluate the purity of glyconanoparticles. By separating components with different hydrophobicity, the target glyconanoparticles, and potential impurities or degradation products can be identified.
- HIC technology can accurately determine the number and distribution of hydrophobic groups on the surface of glyconanoparticles, providing key information for understanding their biological functions and optimizing their performance.
- HIC technology can be used to study the interaction between glyconanoparticles and other biomolecules.
Advantages
- We provide personalized HIC characterization services, tailoring exclusive analysis solutions based on the specific needs and sample characteristics of our clients.
- Our technical team consists of a group of experienced scientists and engineers who have a deep professional background and rich practical experience in HIC technology and glyconanoparticle characterization.
- We not only provide HIC characterization services but also combine other advanced characterization methods to conduct a comprehensive analysis of glyconanoparticles.
Publication
Technology: A novel method to quantitatively measure the surface hydrophobicity of nanoparticles
Published: 2018
Journal: Communications Chemistry
IF: 5.96
Results: The article discusses a novel method to quantitatively measure the surface hydrophobicity of nanoparticles. Traditional methods only offer qualitative assessments of hydrophobicity, which is a critical factor influencing the interaction of nanoparticles with biological systems. The new technique involves assessing the binding affinity of nanoparticles to surfaces engineered with varying degrees of hydrophobicity, utilizing a dark-field microscopy approach to evaluate adsorption kinetics.
Fig.1 The proposed method for quantification of the hydrophobicity of nanomaterials. (Valsesia, et al., 2018)
Frequently Asked Questions
- What is HIC technology and what role does it play in the characterization of glyconanoparticles?
HIC, or hydrophobic interaction chromatography, is a chromatographic technique that separates based on differences in the hydrophobicity of molecular surfaces. In the characterization of glyconanoparticles, HIC technology can accurately determine the hydrophobicity of glyconanoparticles, which is an important parameter for evaluating their biological activity, stability, and interaction ability. Through HIC technology, we effectively separate glyconanoparticle components with different hydrophobicities, thereby helping clients gain a deeper understanding of the physicochemical properties and potential applications of their products.
-
Do your services support personalized customization?
Yes, we pay great attention to the personalized needs of our clients. Our HIC characterization service supports personalized customization, including customized analysis solutions, optimized HIC conditions, and customized data analysis reports based on the specific needs and sample characteristics of clients. Our technical team will communicate with clients throughout the process to ensure that the service process meets client expectations and requirements.
At CD BioGlyco, we specialize in providing HIC-based glyconanoparticle characterization services, offering precise measurements of hydrophobicity and comprehensive analysis of glyconanoparticles' properties. Through advanced HIC technology, we provide clients with detailed insights into their products' purity, surface properties, and interactions with other biomolecules. We tailor our services to meet individual needs, ensuring high-quality results and timely delivery. For more information or to discuss your specific requirements, please contact us.
Reference
- Valsesia, A.; et al. Direct quantification of nanoparticle surface hydrophobicity. Communications Chemistry. 2018, 1(1): 53.
This service is for Research Use Only, not intended for any clinical use.